Walraven Pacifyre® BFC

Basic fire collar for plastic and multi-layer pipes

U0438 Produktlinje: Walraven Pacifyre®Anvendelse: Passive fire protection solutions / Pacifyre

Features & benefits

  • Easy to install
  • Suitable for damp conditions
  • Oversized for increased flexibility in positioning
  • Up to 2 hours fire protection in wall penetrations
  • Up to 4 hours fire protection on floor penetrations
  • Low height increases installation flexibility
  • For thin- and thick-walled pipes
  • For flexible walls, solid walls and floors
  • With a fire resistance up to EI 120 U/C
  • Tested and approved according to EN 1366-3

Artikler

Walraven Pacifyre® BFC
Oversigt over artikler
Varenr. VVS Number Outside Pipe Diameter Inner Diameter Outer Diameter Total Height Total Width Total Depth Number Of Fixations Needed Liste over gemte artikler
Reference Letter D ID OD H W DtT
Unit description (mm) (mm) (mm) (mm) (mm) (mm)
Walraven Pacifyre® BFC 0-50mm 2133000050 18067350 0 - 50 56 70 44 31 267 2
Walraven Pacifyre® BFC 51-63mm 2133000063 18067363 51 - 63 67 90 44 33 313 3
Walraven Pacifyre® BFC 64-75mm 2133000075 18067375 64 - 75 80 100 44 33 345 3
Walraven Pacifyre® BFC 76-90mm 2133000090 18067390 76 - 90 98 125 44 35 423 3
Walraven Pacifyre® BFC 91-110mm 2133000110 18067410 91 - 110 118 150 58 35 487 3
Walraven Pacifyre® BFC 111-125mm 2133000125 18067425 111 - 125 130 160 44 37 533 4
Walraven Pacifyre® BFC 126-140mm 2133000140 18067440 126 - 140 145 180 44 39 595 4
Walraven Pacifyre® BFC 141-160mm 2133000160 18067460 141 - 160 165 200 44 39 659 4